Instructions for the Installer
TYPE OF GAS
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg

Important safety requirements

This hob must be installed in accordance with the Gas Safety (Installation and
Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current
Edition).
Detailed recommendations are contained in the following British Standards
Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current
Editions.
The hob should not be installed in a bed sitting room with a volume of less
than 20 m
effective area of 110 cm
between 5 m
while if the volume exceeds 11 m
However, if the room has a door which opens directly to the outside no air vent
is required even if the volume is between 5 m
If there are other fuel burning appliances in the same room, B.S. 5440 Part 2
Current Edition, should be consulted to determine the requisite air vent
requirements.
12
BURNER
POSITION
NOMINAL THERMAL
POWER
kW
NOMINAL FLOW
RATE
m
/h
3
NOZZLE REFERENCE
1/100 mm
NOMINAL THERMAL
POWER
kW
NOMINAL FLOW
RATE
g/h
NOZZLE REFERENCE
1/100 mm
. If it is installed in a room of volume less than 5 m
3
is required. If it is installed in a room of volume
2
and 10 m
an air vent of effective area of 50 cm
3
3
RAPID
SEMI-RAPID
(large)
(medium)
MAX
MIN
MAX
2.9
0.65
1.9
0.276
0.062
0.181
119
Adjust.
96
2.7
0.65
1.9
195
46.8
137
86
40
71
no air is required.
3
and 11 m
3
AUXILIARY
(small)
MIN
MAX
MIN
0.45
1.0
0.33
0.043
0.095
0.031
Adjust.
70
Adjust.
0.45
1.0
0.33
32.4
72
23.8
32
50
28
an air vent of
3
is required,
2
.
3