Fujitsu RSG36KMTA 운영 매뉴얼 - 페이지 15

{카테고리_이름} Fujitsu RSG36KMTA에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu RSG36KMTA 16 페이지.

Fujitsu RSG36KMTA 운영 매뉴얼
Noise is heard.
□ Is the unit operating, or immediate after stopping operation?
In this case, refrigerant flowing sound may be heard. It may be
particularly noticeable for 2-3 minutes after starting operation.
□ Do you hear a slight squeaking sound during the operation?
This sound is produced by the minute expansion and contraction
of the front panel caused by temperature change.
□ <In the Heating mode> Do you hear a sizzling sound?
This sound is produced by the Automatic defrosting operation.
(Refer to page 11.)
Smell coming from the unit.
□ The air conditioner may absorb various smells generated from
interior textile, furniture, or cigarette smoke. These smells may be
emitted during the operation.
Mist or steam is emitted from the unit.
□ <In the Cooling or Dry mode> A thin mist may be generated by
condensation formed with sudden cooling process.
□ <In the Heating mode> Is [ ] indicator on the indoor unit blinking?
In this case, steam may rise from the outdoor unit because of the
Automatic defrosting operation. (Refer to page 11.)
Outdoor unit emits water.
□ <In the Heating mode> The outdoor unit may emit water gener-
ated by the Automatic defrosting operation. (Refer to page 11.)
The unit operates differently from the remote controller setting.
□ Are the batteries in the remote controller exhausted?
⇒ Replace the batteries.
□ Do you use the group control?
In this case, if the Energy saving program (Occupancy sensor) on
the wireless remote controller is activated, you cannot operate the
air conditioner by the wireless remote controller.
⇒ Deactivate the Energy saving program. (Refer to page 7.)
Operation is delayed after restart.
□ Has the power supply turned from Off to On suddenly?
In this case, the compressor will not operate for about 3 minutes
to prevent a blowout of the fuse.
Immediately stop operation and turn off the electrical breaker in
following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or
diagnostics.
• On the indoor unit, [ ] and [
NOTE: For any troubleshooting related to the WLAN control, refer to
the setting manual for WLAN adapter or the mobile app installed
in your smartphone or tablet PC.
] blink while [
] is blinking fast.
■ State of indicator lamps
: The instruction is relating to the wireless LAN control
(optional).
Lighting pattern:
Blinking,
State
Causes and solutions
Automatic defrosting operation
⇒ Wait until finishing the defrosting
(maximum of 15 minutes).
Filter indicator
⇒ Clean the air filter and reset the filter
sign.
(3 times)
Error code display
⇒ Consult authorized service personnel.
(Fast)
Timer setting error because of Auto restart
⇒ Reset the clock and timer settings.
Test run operation (for authorized
personnel only)
⇒ Press
The power to the access point is not
on.
⇒ Check that the power to the access
point is on.
(Slow)
There is a possibility that the WLAN
adapter is not properly connected to
the access point.
⇒ Disconnect the power supply to the air
conditioner (via breaker or plug), and
then re-connect.
The firmware of the WLAN adapter is
being updated. You cannot operate
the air conditioner from the mobile
app. Operate from the remote
(Fast)
controller or wait until the update
is complete (for a maximum of
5 minutes).
During the air conditioner registration
(pairing of WLAN adapter)
The indoor unit is preparing the
firmware update.
You cannot operate the air
conditioner. Wait until the update is
complete (for a maximum of
30 minutes).
<While the operation is stopped>
The indoor unit is in the firmware
update.
You cannot operate the air
or
conditioner. Wait until the update is
complete (for a maximum of
30 minutes).
Restricted function
<While the operation is stopped>
The firmware update of the indoor
unit is complete. The settings from
(Slow)
the wireless remote controller are
initialized.
Control the air conditioner from the
wireless remote controller to resend
the settings.
Any state (
Off or
On)
page
to quit the test run.
See
11
10
-
11
3
-
11
13
12
13
13
11
13
En-14