Fujitsu UTY-RNRUZ2 설치 매뉴얼 - 페이지 7

{카테고리_이름} Fujitsu UTY-RNRUZ2에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu UTY-RNRUZ2 11 페이지. Remote controller (wired type)
Fujitsu UTY-RNRUZ2에 대해서도 마찬가지입니다: 운영 매뉴얼 (26 페이지)

Fujitsu UTY-RNRUZ2 설치 매뉴얼
6.3.4. R.C. Group Name Setting
Touch the [R.C. Group Name Setting] on the "Initial Setting" screen. The
"R.C. Group Name Setting" screen is displayed.
• About the "R.C. Group Name Setting" screen
Touch the relevant key and enter a
name. Touch [OK] to return to the
"Initial Setting" screen after dis-
playing the "Confirmation screen".
(a) Input area: If the number of input characters exceeds that permitted,
"Over" will be displayed on the right side.
(b) Character keys: Touch the same key until the character you wish to
use is displayed.
(c) Fixed Phrase key: Floor, Corridor, Office, Conf Room, Recept Room,
Room, Room No., Front, Side, Entrance, Outlet, East, West, South,
North, Window are registered. Touch the [Fixed Phrase] key until the
sentence you wish to use is displayed.
(d) Space key
(e) Backspace key
(f) Cursor keys
6.3.5. RC Sensor Setting
1.
Touch the [RC Sensor Setting] on the
"Initial Setting" screen. The "RC Sensor
Setting" screen is displayed.
If a remote-control sensor is used, touch
[Used]. Touch [OK] to return to the "Initial
Setting" screen.
When set to [Not Used] by this setting, the following functions cannot
be used: (Refer to the operating manual on the accessory CD-ROM.)
• Custom Auto in the operation mode. Refer to [2 CONTROL] → [2-2
Operation Settings] → [2-2-1 Set the Operation Mode].
• Away Setting. Refer to [3 SETTING] → [3-5 Special Setting] → [3-5-5
Away Setting].
• Optimum Start Setting. Refer to [3 SETTING] → [3-8 Initial Setting] →
[3-8-9 Optimum Start Setting].
6.3.6. Master Indoor Unit Setting
• One of the multiple indoor units connected to the same refrigerant sys-
tem or RB unit can be set as the "master unit".
• The indoor unit defined as the "master unit" determines the priority mode
(cool or heat) within the refrigerant system or RB group.
• Switch setting on the outdoor unit or RB unit that is connected to the
indoor units. Refer to the installation manual of outdoor unit or RB unit.
1.
Touch the [Master Indoor Unit Setting] on the "Initial Setting"
screen. The "Master Indoor Unit Setting" screen is displayed.
To set a unit as the Master Indoor Unit, touch [Set].
2.
Touch [Yes] when the confirmation screen is displayed to return to
the "Master Indoor Unit Setting" screen.
1.
2.

Master Indoor Unit Setting

Master Indoor Unit Setting
Master Indoor Unit Setting
Not Master Indoor Unit
The connected indoor unit will be
set as the master indoor unit. OK?
No
Back
Set
When changing the Master Indoor Unit, another indoor unit cannot be
made the master indoor unit unless the settings of the current master
indoor unit are cancelled beforehand.
("Reset" cannot be performed while the indoor unit is operating.)
R.C.Group Name Setting
(a)
ABCDEFGHIJKLM│
Over
ABC
FGH
KLM
PQR
SP
BS
(b)
DE
IJ
NO
ST
UVW
Z./
Fixed
0–9
XY
_–
Phrase
(c)
Cancel
OK
R.C. Sensor Setting
Used
Not Used
Cancel
OK
Yes
6.3.7. Password Setting (administrator password)
Set or change the administrator password.
1.
Touch the [Password Setting] on the "Initial Setting" screen. The
"Password Setting" screen is displayed.
Then touch the [Change Password] on the "Password Setting"
screen. The "Change Password" screen is displayed.
2.
Enter the current password, then touch the [OK].
The default password is "0000" (4 digits).
(d)
(e)
3.
Enter the new password, then touch the [OK]. It returns to the
(f)
"Password Setting" screen.
1.
Password Setting
Change Password
Change Setting
Back
4.
Touch the [Change Setting] on the
"Password Setting" screen. The "Change
Setting" screen is displayed.
5.
The "Change Setting" screen is 3 or 4
pages, they can be switched by the [Previ-
ous Page] or [Next Page]. Items set to be
[On] require the administrator password to
open the setting screen.
Change Setting
Page 2/ 4
Set Temp. Range Setting
[On]
Anti Freeze
[On]
Away Setting
[On]
Previous
Next
Cancel
OK
Page
Page
Items that indoor unit does not support are not displayed.
6.
Touch the relevant item to display the setting screen. Touch [OK]
after touching [On] to return to the "Change Setting" screen. Touch
[OK] on the "Change Setting" screen after setting relevant items to
return to the password setting screen.
7.
Touch the [Back] on the "Password Setting". It returns to the "Initial
Setting" screen.
6.
Auto Off Timer
On
Off
Cancel
OK
6.3.8. Display Item Setting
• Filter Sign
Set to "Visible" to display icons on the "Monitor mode screen" during the
indoor unit filter cleaning period.
1.
Touch the [Display Item Setting] on the "Initial Setting" screen. The
"Display Item Setting" screen is displayed.
Then touch the [Filter Sign] on the "Display Item Setting" screen.
The "Filter Sign" screen is displayed.
2.
Touch [OK] after touching [Visible] or [Invisible] to return to the
"Display Item Setting" screen.
1.
Display Item Setting
Filter Sign
[Visible]
Room Temp.
[Invisible]
Cancel
OK
2.
3.
Change Password
Password Verification
Enter Current Password
Enter New Password
0
0
1
2
3
4
CL
CL
5
5
6
7
8
9
Cancel
Cancel
OK
Password Setting
Change Password
Change Setting
Change Setting
Auto Off Timer
Weekly Timer
Set Temp. Auto Return
Cancel
Change Setting
Page 3/ 4
Change Setting
Human Sensor Setting
[On]
Maintenance
Fan Control for Energy Saving
[On]
Initial Setting
[On]
Previous
Next
Previous
Cancel
OK
Cancel
Page
Page
Page
7.
Password Setting
Change Password
Change Setting
Back
2.
Filter Sign
Visible
Invisible
Cancel
OK
1
2
3
4
6
7
8
9
OK
Back
Page 1/ 4
[Off]
[On]
[On]
Next
OK
Page
Page 4/ 4
[On]
OK
En-7