Water Pressure
The appliance is designed to operate within the following water
pressure limits:
minimum 1 bar (14.5 p. s. i.)
maximum 10 bar (145 p. s. i.)
IMPORTANT!
At more than 10 bar (145 p. s. i.): Install pressure-reducing valve.
At less than 1 bar (14.5 p. s. i.): Unscrew the inlet hose from the appli-
ance at the inlet solenoid valve and remove the flow regulator (to do
this, remove the sieve with needle-nose pliers and remove rubber
washer behind the sieve). Replace sieve. Retain the washer for future
use.
Inlet Hose Connection
The inlet hose provided is 1.2 or 1.3 metres depending on the model. If
a longer inlet hose is required contact your AEG Service Force Centre.
Under no circumstances should hoses be connected together to provide
a longer length.
The rubber washers are either set into the inlet hose threaded connec-
tion or supplied separately in the installation kit. These washers must be
fitted to ensure water tight seals. Do not use any other washer.
1. Connect the hose to the machine with
0
the right angled connector.
Important! Do not overtighten the plastic
nuts on the threaded connectors.
2. Connect the hose end with a straight
connector to the water supply tap with
an 3/4" thread.
Important! Do not overtighten the
plastic nuts on the inlet hose threaded
connectors.
WARNING!
Open the water taps slowly and check
the connections are watertight before
final positioning of the machine.