AEG EWF8024P5WB 사용자 설명서 - 페이지 25
{카테고리_이름} AEG EWF8024P5WB에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AEG EWF8024P5WB 40 페이지.
Flush it out under a tap to remove any
traces of accumulated powder.
8.6 Cleaning The Drawer
Recess
Having removed the drawer, use a small
brush to clean the recess, ensuring that
all washing powder residue is removed
from the upper and lower part of the
recess. Replace the drawer and run the
rinse program without any clothes in the
drum.
8.7 Cleaning The Pump
Regularly examine the drain pump
and make sure that it is clean.
Clean the pump if:
The appliance does not drain the water.
The drum cannot turn.
The appliance makes an unusual noise
because of the blockage of the drain
pump.
The display shows an alarm code
because of the problem with water
drain.
WARNING!
1. Disconnect the mains plug from the
mains socket.
2. Do not remove the filter while the
appliance is operating. Do not clean
the drain pump if the water in the
appliance is hot. The water must be
cold before you clean the drain pump.
To clean the drain pump:
1. Open the drain pump door.
2. Place a suitable water container
below the recess of the drain pump
to collect the water that flows out.
Press the two levers and pull forward
the drainage duct to let the water flow
out.
ENGLISH
25
ENGLISH
25