Fujitsu BS2000 SE Series 빠른 매뉴얼 - 페이지 16
{카테고리_이름} Fujitsu BS2000 SE Series에 대한 빠른 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu BS2000 SE Series 43 페이지. Server unit x86
Fujitsu BS2000 SE Series에 대해서도 마찬가지입니다: 매뉴얼 (42 페이지), 운영 매뉴얼 (22 페이지), 운영 매뉴얼 (20 페이지), 운영 매뉴얼 (25 페이지)
3.1 How do I power on Server Units and other units via the SE Manager?
Powering on the Server Unit
Requirement
Login into the SE Manager as administrator, BS2000 administrator or a privileged operator.
The unit is powered off (power status OFF).
In case of an SU /390, an existing connection to the hardware interface is required.
Procedure
> In the
Units
table, click the
this action in the following dialog with
The powered-off Server Unit is powered on. As soon as the
or Native BS2000 system have reached the status
i
After a Server Unit has been powered on, depending on the operating mode set, the Native BS2000
system or the monitor system are started up if an automatic startup (auto IPL) has been configured for
this purpose.
Powering on additional units (redundant MU, HNC)
For BS2000 operation on an SU /390 the following units should also be powered on:
In the case of MU redundancy the second MU should also be powered on. Only in this way will it remain possible
to continue operating the SVP of the SU /390 if the first MU crashes. The SE Manager on the second MU will
also remain available.
To enable the BS2000 systems to communicate over the IP network and ensure access to Net-Storage is
possible, the HNC must be powered on. Redundant existing HNCs should also be powered on.
Power On
icon for the desired Server Unit (in this example an SU300) and confirm
Execute
:
INIT_ONLY
Power status
for the Server Unit is
, you can boot the BS2000.
ON
and the monitor
16