Powering on/off via iRMC
Click iRMC and Open in the Operation tab in the Operation group.
Ê
i
Click Login in the window of the iRMC's web interface, enter user name and password
Ê
in the login window and click OK.
After a successful login the browser window displays the System Overview menu item of
the iRMC's graphical user interface. The System Status group shows that the AU is
powered off.
30
In the case of a partitionable AU (e.g. AU87), systems run on the individual
partitions of the AU. You operate a partition via the Management Board. Open
the web interface of the Management Board in the Operation group instead of
the iRMC:
Powering on/off Application Units