Replacing the power supply unit
Figure 12: Inserting the power supply unit
Ê Push the power supply unit in direction of the server's rear side until it
engages in the chassis.
Ê Fasten the power supply unit with four screws on the server's rear side (see
figure 9 on page 26).
Ê Route the power cables in the same way as for the old power supply unit.
I
If the spare power supply unit is equipped with a cable clamp (as in
figure 10) it is possible to retain the cables in the shown way. Otherwise
route the cables where you find enough free space.
Ê Connect the power supply cables to the system board and to the drives (see
cabling in the Options Guide).
Ê Install the memory air duct (for a detailed description see the Options
Guide).
Ê Install the system fan (for a detailed description see the Options Guide).
Ê Install the processor fan 2 (for a detailed description see the Options Guide).
Ê Close the server (for a detailed description see the Options Guide) and
connect the power plug.