Switching the Server Unit on/off

2.1 Switching the Server Unit on/off
Information on switching on and starting the SE server and on switching it off and shutting
it down is provided in the

2.1.1 Switching the Server Unit on

Before the Server Unit is switched on, the status indicator lights up green (item 5 in
on page
As the administrator or a privileged operator, switch on the Server Unit using the
Ê
SE Manager (menu Hardware → Server (SE<model>, Units tab, "Switch on" function for
the Server Unit), see the "Operation and Administration" manual [5].
The power-on indicator lights up green. The Server Unit switches on, conducts a system
test and starts X2000.
If automatic IPL is configured for BS2000, the BS2000 system (Native or as a VM2000
monitor system) is also started with the configured settings.
If automatic startup is configured for XenVMs, these systems are also started.

2.1.2 Switching the Server Unit off

Before the Server Unit is switched off, the On/Off switch / status indicator lights up green,
and after the Server Unit has been switched off it no longer lights up (item 4 in
page
10).
As the administrator or a privileged operator, switch off the Server Unit using the
Ê
SE Manager (menu Hardware → Server (SE<model>, Units tab, "Switch off" function for
the Server Unit), see the "Operation and Administration" manual [5].
When the Server Unit is switched off, the BS2000 system is shut down properly taking into
account the remaining runtime specified.
The "Power cable connected" status indicator (item 5 in
when the server is switched off but connected to the power supply (power cable connected).
This status indicator does not light up in the following situations:
The Server Unit is switched off and not connected to the power source.
The Server Unit is switched on and operating normally.
8
"Basic Operating
10).
Manual" [1], "Switching the server on and off".
figure 2 on page
Server Unit SU300
figure 2
figure 2 on
10) lights up green
U41860-J-Z126-1-76