Solaris OS Issues and Workarounds for All Supported Releases (Continued)
TABLE 7
CR ID
Description
6723202
The raidctl command cannot be used to
create a hardware RAID using the onboard
SAS/LSI controller on the SPARC Enterprise
M3000 server.
The raidctl command can be used to view
disk/controller status, and can be used on any
PCI Host Bus Adapter (HBA) installed in the
system.
6745410
Boot program ignores the Kadb option which
causes the system not to boot.
6765239
If a SAS device containing multiple SAS
targets is connected to the onboard external
SAS interface, it will not work properly. The
enumeration of target IDs within the device
may change across reboots.
6872501
If 139555-08 has been applied to the domain,
cores are not offlined when requested by the
XSCF. This CR effects only Solaris 10 5/09,
Solaris 10 10/09, and an earlier version of
Solaris OS with patch 139555-08.
6888928
IPMP interface fails since probe packets are
not sent through that interface. Problem occurs
with M3000/M4000/M5000/M8000/M9000
servers running any Solaris release running
IPMP with patch 141444-09 installed.
26
SPARC Enterprise M3000 Server Product Notes for XCP Version 1093 • July 2010
Workaround
No workaround is available.
This issue will not be fixed.
Use kmdb instead of kadb.
Use a FUJITSU SAS card
(SE0X7SA1F/SE0X7SA1X). Alternatively,
check for the availability of a patch for this
defect.
This has been fixed in patch 143359-02.
[Workaround]
Use fmdump(8) with its -v option on the
Service Processor to identify the faulty core.
Once identified, use psradm(1M) on the
domain to offline the core.
This has been fixed in patch 142900-02.
[Workaround]
Disable probe-based failure detection.