Fujitsu ETERNUS AF650 S2 구성 매뉴얼 - 페이지 13
{카테고리_이름} Fujitsu ETERNUS AF650 S2에 대한 구성 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu ETERNUS AF650 S2 18 페이지. Hybrid storage systems, all-flash arrays, power synchronized unit
Fujitsu ETERNUS AF650 S2에 대해서도 마찬가지입니다: 안전 주의사항 (12 페이지)
FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series
2.3.
Hardware Layout
Protection against power supply problems or other disasters at the installation site requires that hardware units be physically installed in
different sites.
Accordingly, install duplicate hardware units in different buildings, on different floors, or in different racks.
Whether management servers are also installed at different sites depends on whether redundancy is used.
The following figure shows a layout in which management server redundancy is not used.
A
Business servers
Fibre Channel switch
Business drives
(using Storage Cluster for clustering)
ETERNUS AF/DX
The business servers, Fibre Channel switches, and storage systems are installed in different buildings, on different floors, or in different racks.
By clustering the business servers and the storage systems between different sites, business continuity can be maintained in the event of a
problem that affects the entire site.
Install the management server at a different site to prevent it from being affected by the problems in the business servers and storage
systems.
Copyright 2016-2017 FUJITSU LIMITED
C
Management server
Clustered
Clustered
Figure-6 Layout in which management server redundancy is not used
B
Business drives
(using Storage Cluster for clustering)
ETERNUS AF/DX
Legend
Page 13 of 18
Business servers
Fibre Channel switch
Building/machine room/rack
SAN
LAN, used for operation and monitoring
http://www.fujitsu.com/eternus/