{카테고리_이름} Fujitsu ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS AF에 대한 구성 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS AF 29 페이지. Fibre channel/ eternus dx500 s4/dx600 s4, eternus dx500 s3/dx600 s3, eternus dx8700 s3 hybrid storage systems, eternus dx400 s2 series, eternus dx8700 s2 disk storage systems, eternus af650 s2, eternus af650 all-flash arrays settings for bs2000 connection
Chapter 4 Set Up the ETERNUS DX/AF Storage System for BS2000
4.5 Creating the LUN Groups/Affinity Groups
4.5
Creating the LUN Groups/Affinity Groups
Set the LUN groups which will be accessible by the BS2000 server.
Controller
DX/AF series
ETERNUS DX/AF storage system:
A maximum of 4096 LUNs per FC port of the storage system is supported for connections to the BS2000 server
depending on the server model.
Please be aware that if the storage system is configured for 4096 LUNs per FC port, the number of host FC
ports per CA port is limited to 32.
SE Server (SU /390):
A maximum of 4096 volumes can be configured in an affinity group, i.e. for a connection from one FC channel
to one FC port in the RAID system. However, we recommend assigning significantly fewer volumes to an
affinity / LUN group so that PAV alias devices can also be generated on the same channel path.
S-Server:
A maximum of 256 volumes can be configured in an affinity group as a maximum of 256 volumes is
supported per channel path, i.e. for a connection from one FC channel to one FC port in the RAID system.
However, we recommend assigning significantly fewer volumes to an affinity / LUN group so that PAV alias
devices can also be generated on the same channel path.
SE Server (SU x86) and SQ-Server:
A maximum of 1024 DX/AF volumes is supported per affinity / LUN group and HBA port (server). No free
volumes in the affinity group are required for PAV alias devices.
4.6
Configuring the Host Affinity
Allocate the WWN of each server to an affinity and specify the accessible LUNs. This sets the access restrictions
for each server connected to the ETERNUS DX/AF storage system.
To recognize a LUN which has the same configuration for multiple Fibre Channel cards, such as in multipath
and cluster configurations, add settings to assign these Fibre Channel cards to the same Host Affinity.
Controller
DX/AF series
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection-
Connectivity > LUN Group
Connectivity
19
Copyright 2018 FUJITSU LIMITED
Category
Category
Action
Add LUN Group
Action
Create Host Affinity
P3AM-5672-10ENZ0