Fujitsu ETERNUS4000 400 서버 연결 매뉴얼 - 페이지 18
{카테고리_이름} Fujitsu ETERNUS4000 400에 대한 서버 연결 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu ETERNUS4000 400 25 페이지. Disk storage systems (fibre channel) for oracle solaris
Fujitsu ETERNUS4000 400에 대해서도 마찬가지입니다: 매뉴얼 (28 페이지), 매뉴얼 (21 페이지), 서버 연결 매뉴얼 (32 페이지), 연결 매뉴얼 (19 페이지)
Chapter 8 ETERNUS Disk Storage System Logical Unit Recognition
>
8.2 When Unidirectional CHAP Authentication is Used
8.2
When Unidirectional CHAP Authentication is Used
Procedure
1
2
3
4
4-1
4-2
4-3
5
6
6-1
6-2
6-3
6-4
7
8
P3AM-4152-02ENZ0
ETERNUS Disk storage systems Server Connection Guide (iSCSI) for Linux
(SUSE Linux Enterprise Server)
Start YaST and then run the iSCSI Initiator in Miscellaneous.
Select the "Discovered Targets" tab and click the [Discovery] button to open the
iSCSI Initiator Discovery dialog.
Set the IP address for the ETERNUS Disk storage system iSCSI port in "IP
Address".
Keep the default port number value (3260).
Select "Outgoing Authentication" for unidirectional CHAP authentication.
Enter the UserName that is set in iSCSI Host of the ETERNUS Disk storage system in
"UserName".
Enter the Password that is set in iSCSI Host of the ETERNUS Disk storage system in
"Password".
Click the [Next] button.
Check that the desired Target is visible in the "Discovered Targets" tab.
The "Connected" state of the Target should be "False" at this time.
Select the desired Target in the "Discovered Targets" tab, and click the [Log In]
button to re-open the CHAP selection dialog.
Select "Outgoing Authentication" for unidirectional CHAP authentication.
Enter the UserName that is set in iSCSI Host of the ETERNUS Disk storage system in
"UserName".
Enter the Password that is set in iSCSI Host of the ETERNUS Disk storage system in
"Password".
Click the [Next] button.
After both path logins have completed, check that the information of the desired
Target is visible in the "Connected Targets" of the iSCSI Initiator Overview.
Make sure that "Start-Up" for the desired Target is set to "automatic" (if currently
set to "manual", select the Target and click the [Toggle Start_Up] button), then
click the [Finish] button.
18
End of procedure
Copyright 2010 FUJITSU LIMITED