Fujitsu ETERNUS4000 400 연결 매뉴얼 - 페이지 10
{카테고리_이름} Fujitsu ETERNUS4000 400에 대한 연결 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu ETERNUS4000 400 19 페이지. Disk storage systems (fibre channel) for oracle solaris
Fujitsu ETERNUS4000 400에 대해서도 마찬가지입니다: 매뉴얼 (28 페이지), 매뉴얼 (21 페이지), 서버 연결 매뉴얼 (25 페이지), 서버 연결 매뉴얼 (32 페이지)
Chapter 3 Setting Up the Server
>
3.1 Creating a WWN Instance Management Table for the Server
2
3
4
4-1
P3AM-4562-01ENZ0
ETERNUS Disk storage systems Server Connection Guide for Oracle Solaris
The instance number that corresponds to the physical path in which the Fibre Channel
card is installed is stored in the "/etc/path_to_inst" file at Fibre Channel card driver
installation. Extract the necessary lines using the "grep" command.
# grep "bfa" /etc/path_to_inst
Example
# grep "bfa" /etc/path_to_inst
"/pci@7c0/pci@0/pci@8/bfa@0"
"/pci@7c0/pci@0/pci@8/bfa@0,1" 1 "bfa"
Physical path name
Enter the results in "Instance name" and "Physical path name" columns of the
"WWN instance management table for the server".
Example
Physical slot name
WWN
Enter the slot number of the Fibre Channel card installed in the server in the
"Physical slot number" field of the "WWN instance management table for the
server".
Use the "/usr/platform/`uname -i`/sbin/prtdiag -v" command to check the installed Fibre
Channel card slot number.
Example: Excerpt from "/usr/platform/SUNW,SPARC-Enterprise-T5220/sbin/prtdiag -v"
output
# /usr/platform/SUNW,SPARC-Enterprise-T2000/sbin/prtdiag -v
========================= IO Configuration ===============================
Location
Type Slot
Path
--------------------------------------------------------------------------
IOBD/PCIE1
PCIE 1
/pci@7c0/pci@0/pci@8/bfa@0
IOBD/PCIE2
PCIE 2
/pci@7c0/pci@0/pci@8/bfa@0,1
Physical slot name
WWN
PCIE1
PCIE2
Check the WWN for the Fibre Channel card.
Use the following command to check the display order of the Fibre Channel card
physical path names.
# prtpicl -v -c scsi-fcp | grep devfs-path
Example
# prtpicl -v -c scsi-fcp | grep devfs-path
:devfs-path
:devfs-path
0 "bfa"
Instance number
Controller name
Instance name
bfa0
bfa1
Controller number
Instance name
bfa0
bfa1
/pci@7c0/pci@0/pci@8/bfa@0
/pci@7c0/pci@0/pci@8/bfa@0,1
10
Physical path name
/pci@7c0/pci@0/pci@8/bfa@0
/pci@7c0/pci@0/pci@8/bfa@0,1
Name
Model
bfa-pciex1657,13 Brocade-8+
bfa-pciex1657,13 Brocade-8+
Physical path name
/pci@7c0/pci@0/pci@8/bfa@0
/pci@7c0/pci@0/pci@8/bfa@0,1
Copyright 2010 FUJITSU LIMITED