Fujitsu ETERNUS8000 900 매뉴얼 - 페이지 16
{카테고리_이름} Fujitsu ETERNUS8000 900에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu ETERNUS8000 900 21 페이지. Disk storage systems (fibre channel) for oracle solaris
Fujitsu ETERNUS8000 900에 대해서도 마찬가지입니다: 매뉴얼 (28 페이지), 서버 연결 매뉴얼 (25 페이지), 서버 연결 매뉴얼 (32 페이지), 연결 매뉴얼 (19 페이지)
Chapter 3 Setting Up MPxIO
>
3.3 Solaris 8 OS
3.3
Solaris 8 OS
3.3.1
Disabling MPxIO on Some Paths
When multipathing is not required for some devices, the procedure that follows should be used to
add the physical paths of these devices to the "/kernel/drv/fp.conf" file, in order to disable use of
the multipath function for these devices.
This is not necessary when multipathing is to be set up for all devices recognized by the OS, in
which case proceed to
Procedure
1
2
P3AM-2722-04ENZ0
ETERNUS Disk storage systems Server Connection Guide for Oracle Solaris
"3.3.2 Checking the Storage System Status" (page
If this setting is omitted, multipathing is set up for all LUNs recognized by
the OS.
MPxIO must be disabled for the paths of connected devices that MPxIO
does not support (such as a tape device).
Use the "cat" command (etc.) to check the "/etc/path_to_inst" file and identify the
physical pathname of the device for which multipathing is not required.
In this example, the physical path is "/pci@8,600000/SUNW,qlc@2"
# cat /etc/path_to_inst
"/pci@8,600000/SUNW,qlc@2" 0 "qlc"
"/pci@8,600000/SUNW,qlc@2/fp@0,0" 5 "fp"
"/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0113ce2e1,0" 5 "ssd"
Physical path
Add the following line to the "/kernel/drv/fp.conf" file using the "vi" command.
name="fp" parent="Physical path" port=0 mpxio-disable="yes";
Example:
name="fp" parent="/pci@8,600000/SUNW,qlc@2" port=0 mpxio-disable="yes";
16
17).
End of procedure
Copyright 2010 FUJITSU LIMITED