Fujitsu MB2146-440-E 설정 매뉴얼 - 페이지 14

{카테고리_이름} Fujitsu MB2146-440-E에 대한 설정 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu MB2146-440-E 19 페이지. F2mc-8fx family mb95330 series 8-bit microcontroller ev board
Fujitsu MB2146-440-E에 대해서도 마찬가지입니다: 설정 매뉴얼 (23 페이지)

Fujitsu MB2146-440-E 설정 매뉴얼
3 EV Board Operation

3.1 Connect the Motor Connector and the Hall Sensor Connector

Before power on, connect the motor lines to the motor connector and the hall sensor
connector according to the following direction. Refer to Figure 3-1.
Note: If the driving method is Back EMF, the hall sensor connector should not be connected.
Figure 3-1: Connect Motor Connector and Hall Sensor Connector

3.2 Select the Driving Method as Hall Sensor or Back EMF

If you want to select the hall sensor, the switchers are set as J1(2-3),J2(2-3), and J3(2-3).
Otherwise, the switchers are set as J1(1-3),J2(1-3), and J3(1-3). Switch on the power and
the power LED turns
on.
you want to change the FW driving method, press the hall sensor/B-EMF key when the
motor is stopped. Then, the LED3 turns off. It means the FW driving method is hall sensor.
Refer to Figure 3-2.
Notes: the selection of the FW driving method should match with the selection of switchers.
EV BOARD MB2146-440-E V1.4
Chapter 3 EV Board Operation
When the LED3 is on, it means the FW driving method is B-EMF. If
MCU-AN-500070-E-14 – Page 14
W
V
U
Motor connector
GND
H3
H2
Hall sensor connector
H1
5V