3.6 LIN"A" (JP: 17, 18, 21, 22, 44)
One LIN-transceiver (U5, X8) can be connected to one of the microcontroller's UART
interfaces.
JP17
enable LIN-Transceiver
JP18
LIN Master-mode
JP21, JP22 connects UART 0 to the LIN-transceiver (U5, X8)
If the LIN interface is not used then the jumpers should be left open.
Jumper
JP17 (LIN enable)
JP18 (LIN Master)
JP21 (LIN"A"RXD)
JP22 (LIN"A"TXD)
JP44 (VBAT_A)
By default, the LIN"A"-interface is not connected to a UART.
3.7 LIN"B" (JP: 9, 10, 38, 39, 45)
One LIN-transceiver (U4, X6) can be connected to one of the microcontroller's UART
interfaces.
JP9
enable LIN-Transceiver
JP10
LIN Master-mode
JP38, JP39 connects UART 1 to the LIN-transceiver (U4, X6)
If the LIN interface is not used then the jumpers should be left open.
Jumper
JP9 (LIN enable)
JP10 (LIN Master)
JP38 (LIN"B"RXD)
JP39 (LIN"B"TXD)
JP45
(VBAT_B)
By default, the LIN"B"-interface is not connected to a UART.
© Fujitsu Microelectronics Europe GmbH
SK-91464A-100PMC User Guide
Chapter 3 Jumpers and Switches
Setting
Description
Closed
LIN-transceiver is enabled
Open
LIN-transceiver is disabled
Closed
LIN Master-mode
Open
LIN Slave-mode
Closed
SIN0 of the MCU is connected to LIN"A"
Open
SIN0 of the MCU is not connected to LIN"A"
Closed
SOT0 of the MCU is connected to LIN"A"
Open
SOT0 of the MCU is not connected to LIN"A"
Closed
Vs of LIN A is powered by the board
Open
No voltage supply to Vs of LIN A
Setting
Description
Closed
LIN-transceiver is enabled
Open
LIN-transceiver is disabled
Closed
LIN Master-mode
Open
LIN Slave-mode
Closed
SIN1 of the MCU is connected to LIN"B"
Open
SIN1 of the MCU is not connected to LIN"B"
Closed
SOT1 of the MCU is connected to LIN"B"
Open
SOT1 of the MCU is not connected to LIN"B"
Closed
Vs of LIN B is powered by the board
Open
No voltage supply to Vs of LIN B
- 15 -
FMEMCU-UG-910025-15