2.2. ELECTRICAL CONNECTION:

The electrical connection must be accomplished by an electrician-installer. He must make sure
that the oven has been joined up according to assembly instructions and local regulations. Being
the oven live, the electronics activates interrupting the lighting for any seconds. In case of connection
to a power socket, it must be accessible after the installation of the oven. The manufacturer does
not incur any responsibility in case of a wrong or non-existent earth. The oven is delivered with its
own 3-ways supply cable (cable: H05V2V2F-T90). It must be joined upon the network 220-240 V~
/ 50 Hz / single-phase with an earth plate (rule CEI60083). This earth plate must be easily acces-
sible after the installation of the appliance. Pay attention to the colour of the wires: wall-sockets are
usually joined up according to the scheme below. The section of the conductors must be at least
1,5 mm and the installation must be shielded by a 16A-fuse.
Blue

2.3. TECHNICAL FEATURES:

RISE AND MAINTAINANCE AT
Service Manual
Evolution - 2005
Black, brown or red
NEUTRAL
LIVE
EARTH
Green and Yellow
OPERATING VOLTAGE
TOTAL POWER
ENERGY CONSUMPTION
100°C FOR 1 HOUR
INSIDE DIMENSIONS OF OVEN
WIDTH
HEIGHT
DEPTH
EFFECTIVE VOLUME
STEAM OVEN
220-240 ~ 50Hz
1,77 kWh
0,71 kW
38,5 cm
18,2 cm
33,5 cm
23,5 litres