Indesit FG10(BK) 설치 및 사용 설명서 지침 - 페이지 6
{카테고리_이름} Indesit FG10(BK)에 대한 설치 및 사용 설명서 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Indesit FG10(BK) 18 페이지. Gas built in single oven
Introduction
Glass door panels
To meet the relevant Standards of
Domestic cooking appliances, all the
glass panels on this appliance are
toughened to meet the fragmentation
requirements of BS3193. This ensures
that, in the unlikely event that a panel
breaks, it does so into small fragments
to minimise the risk of injury.
Please take care when handling, using
or cleaning all glass panels as any
damage to the surfaces or edges may
result in the glass breaking without
warning or apparent cause at a later
date.
Should any glass panel be
damaged, we strongly recommend
that it is replaced immediately.
Before using the appliance for
the first time, remove any protective
polythene film and wash the oven
shelves in hot soapy water to remove
their protective covering of oil. Even
so, when you first switch on the oven
or grill you may notice a smell and
some smoke.
Condensation
When hot and cold air meet,
condensation forms. The outer door is air
cooled and the inner door gets hot, so some
condensation might form; this is normal
and will disappear within 10 - 15 minutes.
To replace a light bulb (if fitted)
Caution: Switch off the electricity
supply to the appliance, to avoid the
possibility of electric shock.
Wait until the oven is cool, then
remove the shelves.
Unscrew
the
lens
cover
anticlockwise). Unscrew the bulb and
replace. Replace lens cover.
Please note that light bulbs are not
covered by guarantee.
Environmental Protection
We are committed to protecting the
environment
and
operate
Environmental Management System
which complies with BS EN ISO
14001:1996.
Disposal of packaging
All our packaging materials are
recyclable and environmentally
friendly.
Please help us to protect our
environment by disposing of all
packaging in an environmentally
friendly manner.
Please contact your local authority
for the nearest recycling centre.
Caution: Packaging materials can
pose a risk of suffocation - keep away
from children.
4
Step 5: Commissioning
Pressure test point
Use the oven burner. From inside the
oven remove the burner cowl. Remove
the small screw at the LHS of the
(turn
burner cradle. Slide the burner to the
left to access the injector.
Connect
suitable
(incorporating a 1.25mm injector) to
the injector.
Connect manometer to
the T-piece, and turn oven control to
full on to check pressure.
Replace in reverse order.
an
Burner aeration
All burners have fixed aeration and no
adjustment is possible.
Pressure setting
Cat I
G20 Natural Gas @ - 20mbar
2H
Electrical systems check
In the event of an electrical fault the
preliminary electrical system check
(earth continuity, short circuit, polarity
and resistance to earth) must be
carried out.
Installation Instructions
Oven
1. Push in and turn the control knob
anticlockwise to gas mark 9.
2. Adjust to the required setting.
3. The burner may not come on to a
full rate unless the oven door is
closed.
The oven burner operates at a low
T-piece
rate for up to 60 seconds until the
flame supervision device opens
and full gas rate is obtained.
Grill
1. The door must be open for the grill
burner to ignite.
2. Push in and turn the control knob
clockwise to the grill symbol.
3. Close the door, and check that the
burner goes out.
The grill burner will re-ignite when
the door is opened again.
Before leaving the installation
Show the customer how to ignite
the oven and grill and give them this
handbook. Thank you.
29