Your appliance is supplied with a 13 amp fused plug
that can be plugged into a 13 amp socket for
immediate use. Before using the appliance please
read the instructions below.
WARNING - THIS APPLIANCE MUST BE
EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA
approved fuse to BS 1362 should always be used,
and the fuse cover re-fitted. If the fuse cover is lost,
the plug must not be used until a replacement is
obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of
the correct colour as indicated by the coloured
marking or the colour that is embossed in words on
the base of the plug. Replacements can be obtained
directly from your nearest Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded plug
and you should wish to remove it to add a cable
extension or to re-route the mains cable through
partitions, units etc., please ensure that either:
• the plug is replaced by a fused 13 amp re-
wireable plug bearing the BSI mark of approval.
or:
• the mains cable is wired directly into a 13 amp
cable outlet, controlled by a switch, (in
compliance with BS 5733) which is accessible
without moving the appliance.
! ! ! ! ! For appliances with a rating greater than 13 amp
(eg: electric hob, double ovens and freestanding
electric cookers etc.) the mains cable must be wired
into a cooker output point with a rating of 45 amp. In
this case the cable is not supplied.
Disconnecting the cable
Ensure that the means for disconnection of the
power cable is incorporated into the fixed wiring in
accordance with local wiring rules.
(New Zealand statutory warning): The cooker must
be connected to the electricity supply by a cable
fitted with an appropriately rated plug that is
compatible with the socket-outlet fitted to the final
subcircuit in the fixed wiring that is intended to
supply this cooker.
Disposing of the plug:
Ensure that before disposing of the plug itself, you
make the pins unusable so that it cannot be
accidentally inserted into a socket. Instructions for
connecting cable to an alternative plug:
! ! ! ! ! The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
- Earth
Blue
- Neutral
Brown
- Live
If the colours of the wires in the mains lead do not
correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
Connect Green & Yellow wire to terminal marked "E E E E E "
or or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked "L L L L L " or
coloured Red.
GREEN &
Connect Blue wire to terminal
YELLOW
marked "N N N N N " or coloured Black.
13 amp fuse
BROWN
If a 13 amp plug (BS 1363) is
CROSS-BAR
BLUE
used it must be fitted with a
CORD GRIP
13 amp fuse. A 15 amp plug
must be protected by a 15
amp fuse, either in the plug or
adaptor or at the distribution board. If you are in any
doubt about the electrical supply to your machine,
consult a qualified electrician before use.
How to connect an alternative plug:
The wires in this mains lead are coloured in
accordance with the following code:
B L U E
B L U E
B L U E
B L U E
B L U E
B R O W N
B R O W N
B R O W N
B R O W N
B R O W N
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
Disposing of the appliance
When disposing of the appliance please remove the
plug by cutting the mains cable as close as
possible to the plug body and dispose of it as
described above.
Checking the connection for leaks
Upon completion of installation, check the gas
circuit, the internal connections and the taps for
leaks using a soapy solution (never a flame). Also
check that the connecting pipe cannot come into
contact with moving parts which could damage or
crush it. Make sure that the natural gas pipe is
adequate for a sufficient supply to the appliance
when all the burners are lit
"NEUTRAL
NEUTRAL
NEUTRAL" ("N N N N N ")
NEUTRAL
NEUTRAL
LIVE" ("L L L L L ")
LIVE
LIVE
"LIVE
LIVE
"EARTH
EARTH" ("E E E E E ")
EARTH
EARTH
EARTH
5