Adjusting the gas oven burner's minimum setting:
1. Light the burner ( see Start-up and Use ).
2. Turn the knob to the minimum position (MIN) after
it has been in the maximum position (MAX) for
approximately 10 minutes.
3. Remove the knob.
4. Tighten or loosen the adjustment screws on the
outside of the thermostat pin ( see figure ) until the
flame is small but steady.
! If the appliance is connected to liquid gas, the
adjustment screw must be fastened as tightly as
possible.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.

Table of burner and nozzle specifications

Table 1
Burner
Diameter
(mm)
Nominal Reduced
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
51
(Small)(A)
Oven
-
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C 1013 mbar-dry gas
**
Propane P.C.S. = 50,37 MJ/Kg
Thermal Power
By Pass
kW (p.c.s.*)
1/100
(mm)
3.00
0.7
41
1.90
0.4
30
1.00
0.4
30
2.80
1.0
46
***
Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m³

TECHNICAL DATA

Oven dimensions
(HxWxD)
Volume
Useful
measurements
relating to the oven
compartment
Power supply voltage
and frequency
Burners
Liquid Gas
Natural Gas
Nozzle
Flow*
Nozzle
1/100
g/h
1/100
(mm)
***
**
(mm)
87
218
214
128
70
138
136
104
52
73
71
76
80
204
200
119
28-30
37
20
25
35
45
34x39x44 cm
58 l
width 42 cm
depth 44 cm
height 18 cm
see data plate
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Flow*
l/h
286
A
181
95
267
KN3G2S/FR
20
17
25
GB
S S
R
17