Indesit KNJ3G2/UA 사용 설명서 - 페이지 6
{카테고리_이름} Indesit KNJ3G2/UA에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Indesit KNJ3G2/UA 40 페이지. Cooker and oven
adjustment screw must be fastened as tightly as
GB
possible.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
S S
A
R
KNJ3G2/UA
Table of burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
51
(Small)(A)
Oven
-
Supply
Pressures
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
6
Thermal Power
By-Pass
kW (p.c.s.*)
1/100
Nominal Reduced
(mm)
3.00
0.7
1.90
0.4
1.00
0.4
2.00
1.0
48-49
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
TECHNICAL DATA
Oven dimensions
(HxWxD)
Volume
Useful
measurements
relating to the oven
compartment
Power supply voltage
and frequency
Burners
Liquid Gas
Nozzle
Flow*
1/100
g/h
(mm)
***
41
87
218
30
70
138
30
52
73
68
145
28-30
20
35
34x39x38 cm
58 l
width 42 cm
depth 44 cm
height 17 cm
see data plate
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Natural Gas
Nozzle
Flow*
Nozzle
1/100
l/h
**
(mm)
214
128
286
136
104
181
71
76
95
143
107
190
37
20
25
17
45
25
Flow*
1/100
l/h
(mm)
143
286
118
181
80
95
114
190
13
6,5
18