by the circuit-breaker). The supply cable must not come into contact with
GB
surfaces with temperatures higher than 50°C.
! The installer must ensure that the correct electrical connection has been
made and that it is compliant with safety regulations.
Before connecting to the power supply, make sure that:
• the appliance is earthed and the plug is compliant with the law.
• the socket can withstand the maximum power of the appliance, which is
indicated on the data plate.
• the voltage is in the range between the values indicated on the data plate.
• the socket is compatible with the plug of the appliance. If the socket is
incompatible with the plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
! Once the appliance has been installed, the power supply cable and the
electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by authorised technicians
only (see Assistance).
! The manufacturer declines any liability should these safety measures not
be observed.
Gas connection
! This operation must be performed by a qualified technician.
The appliance should be connected to the main gas supply or to a gas
cylinder in compliance with current national regulations. Before carrying out
the connection, make sure the cooker is compatible with the gas supply you
wish to use. If this is not the case, follow the instructions indicated in the
paragraph "Adapting to different types of gas."
When using liquid gas from a cylinder, install a pressure regulator which
complies with current national regulations.
! Check that the pressure of the gas supply is consistent with the values
indicated in Table 1 ("Burner and nozzle specifications"). This will ensure the
safe operation and longevity of your appliance while maintaining efficient
energy consumption.
• The connection of the hob to the
gas pipe network or gas cylinder
must be made by means of a rigid
copper or steel pipe with fittings
complying with local regulations, or
by means of a continuous-surface stainless steel hose complying with local
regulations. Interpose gasket (B) in the elbow connection.The maximum
length of the hose is 2 m.
• FOR BELGIUM ONLY: It is necessary to replace the elbow connection
(A) on the appliance, with the one supplied (if present).
IMPORTANT: if a stainless steel hose is used, it must be installed so as
not to touch any mobile part of the furniture. It must pass through an
area where there are no obstructions and where it is possible to inspect
it on all its length.
• After connection to the gas supply, check for leaks with soapy water. Light
up the burners and turn the knobs from max position
position to check flame stability.
12
Adapting to different types of gas
! This operation must be performed by a qualified technician.
To adapt the hob to a different type of gas other than default type (indicated
on the rating plate at the base of the hob or on the packaging), the burner
nozzles should be replaced as follows:
1. Remove the hob grids and slide the burners off their seats.
2. Unscrew the nozzles using a socket spanner of the appropriate size, and
replace them with nozzles for the new type of gas (see table 1 "Burner
and nozzle characteristics").
3. Reassemble the parts following the above procedure in the reverse order.
4. Once this procedure is finished, replace the old rating sticker with one
indicating the new type of gas used. Sticker are available from any of our
Service Centres.
• Adjusting the burners' primary air
Does not require adjusting.
• Setting the burners to minimum
To ensure that the minimum setting is correctly adjusted, remove the knob
and proceed as follows:
2. Having adjusted the flame to the required low setting, while the burner is
alight, quickly change the position of the knob from minimum to maximum
and vice versa several times, checking that the flame does not go out.
3. Some appliances have a safety device (thermocouple) fitted. If the device
fails to work when the burners are set to the low flame setting, increase
this low flame setting using the adjusting screw.
4. Once the adjustment has been made, replace the seals on the by-passes
using sealing wax or a similar substance.
! If the appliance is connected to liquid gas, the regulation screw must be
fastened as tightly as possible.
! Once this procedure is finished, replace the old rating sticker with one
indicating the new type of gas used. Stickers are available from any of our
Service Centres.
! Should the gas pressure used be different (or vary slightly) from the
recommended pressure, a suitable pressure regulator must be fitted to the
inlet pipe (in order to comply with current national regulations).
DATA PLATE
Electrical
connections
ECODESIGN
This appliance conforms to the EU Regulation no. 66/2014
implementing Directive 2009/125/EC.
standard EN 30-2-1
to minimum
1. Adjust the adjustment screw, which is
positioned in or next to the tap pin, until the
flame is small but steady:
• tighten screw to reduce the flame height;
• loosen screw to increase the flame height;
The adjustment must be performed with the
tap in minimum gas setting position.
see data plate