Residual Heat indicator
The Residual Heat indicator light is controlled by a NTC sensor located on the centre of inductors.
According to the power chosen by the user and the time in which the inductor has been turned on, the
temperature will change and the Residual Heat will be displayed:
with "H" (capital letter) to indicate that the temperature of the inductor is very high (over 60°C), and
with "h" (small letter) to indicate that the temperature of the inductor is included between 60°C and 40
°C.
Springs on slide supports.
The function of the springs located on the slides, where the board and inductors assembly must be fi tted,
it to pull this assembly upwards to assure a complete and correct contact between the inductor and the
glass top.

3.1: WIRING DIAGRAM

Legend:
A Power supply
B Small inductor
C Large inductor
D Small inductor NTG
E Large inductor NTG
F
Display board
Service Manual
Induction hob manual
F
E
D
Edition
2008.03.01
11
A
B
C
Language
English