Indesit TIP 642 DD L 서비스 매뉴얼 - 페이지 11
{카테고리_이름} Indesit TIP 642 DD L에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Indesit TIP 642 DD L 19 페이지.
Residual Heat indicator
The Residual Heat indicator light is controlled by a NTC sensor located on the centre of inductors.
According to the power chosen by the user and the time in which the inductor has been turned on, the
temperature will change and the Residual Heat will be displayed:
•
with "H" (capital letter) to indicate that the temperature of the inductor is very high (over 60°C), and
•
with "h" (small letter) to indicate that the temperature of the inductor is included between 60°C and 40
°C.
Springs on slide supports.
The function of the springs located on the slides, where the board and inductors assembly must be fi tted,
it to pull this assembly upwards to assure a complete and correct contact between the inductor and the
glass top.
3.1: WIRING DIAGRAM
Legend:
A Power supply
B Small inductor
C Large inductor
D Small inductor NTG
E Large inductor NTG
F
Display board
Service Manual
Induction hob manual
F
E
D
Edition
2008.03.01
11
A
B
C
Language
English