Installation

Electrical Connection

Any electrical work required to install this appliance should be carried
out by a qualified electrician or competent person.
WARNING – THIS APPLIANCE MUST BE EARTHED
The manufacturer declines any liability should these safety measures not
be observed.
Before switching on, make sure the electricity supply voltage is the same as
that indicated on the appliance rating plate. The rating plate is inside, on the
left.
The appliance is supplied with a 13 amp plug fitted. In the event of having
to change the fuse in the plug supplied, a 13 amp ASTA approved (BS 1362)
fuse must be used.
Important!
The wires in the mains lead are
coloured in accordance with the
following code:
Green and Yellow Earth
Blue
Brown
As the colours of the wires in the
mains lead of this appliance may not
correspond with the coloured
markings identifying the terminals in
your plug, proceed as follows:
1.
The wire coloured green and yellow must be connected to the terminal
marked with the letter "E" or by the earth symbol or coloured green and
yellow.
2.
The wire coloured blue must be connected to the terminal marked "N" or
coloured black.
3.
The wire coloured brown must be connected to the terminal marked "L" or
coloured red.
4.
Upon completion there must be no cut, or stray strands of wire present and
the cord clamp must be secure over the outer sheath.
Warning! A cut-off plug inserted into a 13 amp socket is a serious safety
(shock) hazard. Ensure that the cut-off plug is disposed of safely.