AEG RCB53426TX 사용자 설명서 - 페이지 6

{카테고리_이름} AEG RCB53426TX에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AEG RCB53426TX 44 페이지.

AEG RCB53426TX 사용자 설명서
6
www.aeg.com
• Do not cause damage to the part of
the cooling unit that is near the heat
exchanger.

3. INSTALLATION

WARNING!
Refer to Safety chapters.
3.1 Positioning
This appliance can be installed in a dry,
well ventilated indoor where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance:
Climate
class
SN
N
ST
T
3.2 Location
It must be possible to
disconnect the appliance
from the mains power
supply. The plug must
therefore be easily
accessible after installation.
The appliance should be installed well
away from sources of heat such as
radiators, boilers, direct sunlight etc.
Ensure that air can circulate freely around
the back of the cabinet. To ensure best
performance, if the appliance is
positioned below an overhanging wall
unit, the minimum distance between the
top of the cabinet and the wall unit must
be at least 100mm. Ideally, however, the
appliance should not be positioned
below overhanging wall units. One or
more adjustable feet at the base of the
cabinet ensure that the appliance stands
level.
Ambient temperature
+10°C to + 32°C
+16°C to + 32°C
+16°C to + 38°C
+16°C to + 43°C
A
CAUTION!
In order to guarantee proper
functioning in ambient
temperature above 38°C, it
is advised to have a 30mm
separation between the
sides of the appliance and
surrounding furniture.
3.3 Levelling
When placing the appliance ensure that
it stands level. This can be achieved by
two adjustable feet at the bottom in
front.
3.4 Electrical connection
• Before plugging in, ensure that the
voltage and frequency shown on the
B