AEG 220 D 설치 및 운영 지침 매뉴얼 - 페이지 8
{카테고리_이름} AEG 220 D에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AEG 220 D 17 페이지. Fume extractor hood
Installation
Safety warnings for kitchen unit installer
When used as an extractor unit, the hood must be fitted
with a 120mm diameter hose.
If the fumes must be forced out through the wall, you
must obtain a MKZ sizable wall exhaust pipe (with
external exhaust and air intake), E-Nr.- 610 899 004 (Ø 120
mm) which is one of our optional parts.
When installing the hood, make sure you respect
the following minimum distance from the top edge
of the cooking hob/ring surfaces:
electric cookers
gas cookers
coal and oil cookers
The hood cannot be connected to flues of other
appliances that run on energy sources other than
electricity.
The air outlet must not be connected to chimney flues or
combustion gas ducts. The air outlet must under no cir-
cumstances be connected to ventilation ducts for rooms in
which fuel-burning appliances are installed.
It is advisable to apply for authorization from the relevant
controlling authority when connecting the outlet to an
unused chimney flue or combustion gas duct.
The air outlet installation must comply with the
regulations laid down by the relevant authorities.
When the unit is used in its extractor version, a
sufficiently large ventilation hole must be provided, with
dimensions that are approximately the same as the outlet
hole.
National and regional building regulations impose a
number of restrictions on using hoods and fuel-burning
appliances connected to a chimney, such as coal or oil
room-heaters and gas fires, in the same room.
24
650 mm
650 mm
700 mm min.