Electrical connection

Safety warnings for the electrician
Before connecting the appliance to the power supply, check that the volt-
age indicated on the rating plate corresponds to the mains power supply
available. Appliances fitted with a plug can be connected to any standard
power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must only
be installed by an electrician authorised by the local electricity board.
When installing, an omnipolar disconnector with a distance of at least 3
mm between contacts must be provided.
This disconnector may be for example a switch, fuses (plug fuses must
be removed from the fuse box, fault current switches and remote switches
with a distance of over 3 mm between contacts.
The manufacture declines all responsibility for malfunctions resulting from
failure to comply with the above instructions.
If the power socket is applied directly above the hood this gives two ad-
vantages:
1. the socket is not visible.
2. the appliance can be disconnected at need merely be removing the
plug.
Electrical connection
220-240 V – by means of fixed power cable with plug.
(Fixed connection of the appliance must only be carried out by an author-
ised electrician.)