Kohler 10EKD 설치 지침 매뉴얼 - 페이지 6

{카테고리_이름} Kohler 10EKD에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler 10EKD 17 페이지.
Kohler 10EKD에 대해서도 마찬가지입니다: 설치 지침 (4 페이지)

Kohler 10EKD 설치 지침 매뉴얼
7.

Install the flow switch.

7.1
For Units Without a Siphon Break:
Note: Proceed to Section 7.2 for units with a
siphon break.
7.1.1 Remove
between the heat exchanger end cap and
catalyst. See Figure 13. Save the molded
hose for re-use.
1
1. Remove this hose.
Figure 13 Hose Location (Units Without Siphon
Break)
7.1.2 Install a new hose (X-312-42), flow switch
(GM90436), and hose fittings (GM90472
qty. 2) as shown in Figure 15.
Note: Use Teflon tape on the threads of
the flow switch fittings. Wrap the
tape around at least 3 times.
Note: Avoid any kinks in hoses that
connect to the flow switch.
7.1.3 Reuse the molded hose (removed in
Step 7.1.1) but spin the hose 180_ from its
original position. See Figure 15, item 1.
7.1.4 Secure the hoses using hose clamps
(X-426-12 qty. 2) and existing hose
clamps.
7.1.5 Connect the flow switch connector to the
new wiring harness connector that was
routed to the nonservice side in Step 5.2.
6
the
molded
hose
located
GM58158-L
7.2
For Units With a Siphon Break:
7.2.1 Remove the hose located between the
heat exchanger end cap and the hose
connector. See Figure 14.
7.2.2 Cut this hose into a 4-inch piece and a
5-inch piece.
1
1. Remove this hose.
Figure 14 Hose Location (Units With Siphon Break)
7.2.3 Reuse the
Step 7.2.2) as shown in Figure 15, item 4.
Install the flow switch (GM90436), and
hose fittings (GM90472 qty. 2) as shown in
Figure 15.
Note: Units equipped with a siphon break
will not use the new hose X-312-42
supplied in the kit.
Note: Use Teflon tape on the threads of
the flow switch fittings. Wrap the
tape around at least 3 times.
Note: Avoid any kinks in hoses that
connect to the flow switch.
7.2.4 Reuse the
Step 7.2.2) as shown in Figure 15, item 2.
7.2.5 Secure the hoses using hose clamps
(X-426-12 qty. 2) and existing hose
clamps.
7.2.6 Connect the flow switch connector to the
new wiring harness connector that was
routed to the nonservice side in Step 5.2.
GM60007-A
hose (cut to 4 inches in
hose cut to 5 inches in
TT-1617
12/13