3.12 Connect
the
clear
(GM34883) to the siphon break cap using a hose
clamp (X-426-9) to secure. Route the tubing to a
convenient location. This allows the seawater to
drip into the bilge and not on the generator set.
3.13 Siphon break mounting varies with each
application. Generally, use brass or stainless
steel screws and mount the siphon break using
the mounting tabs.
(conduit-type) pipe clamp.
Note: Mount the siphon break in a location easily
accessable for inspection and servicing.
Note: Ensure that the siphon break cap is tight before
operating the generator set.
4.
Restore the generator set to service.
4.1
Check that the generator set is OFF.
4.2
Reconnect the generator set engine starting
battery, the negative (--) lead last.
4.3
Reconnect the power to the battery charger, if
equipped.
4.4
Start the generator set and check for water leaks.
4.5
Stop the generator set.
4.6
Replace the sound shield's exhaust panel, door,
and roof.
Inspection/Maintenance
Service the siphon break during regular exhaust system
component inspection. See the generator set operation
manual for the service schedule.
Note: The generator set must not be running during the
siphon break inspection.
1.
Remove the generator set from service.
1.1
Press the start/stop button to stop the generator
set. The engine stops.
1.2
Press the power button to turn off the controller.
1.3
Disconnect the power to the battery charger, if
equipped.
1.4
Disconnect the generator set engine starting
battery, the negative (--) lead first.
TT-1509
4/14
flexible
plastic
tubing
Otherwise, use a nylon
2.
Inspect the siphon break.
2.1
Remove the retaining cap and remove the reed
valve for inspection. See Figure 5.
2.2
Use a mild detergent to remove residue and
oxidation from the reed valve.
2.3
Clear blockage from the reed valve opening.
2.4
Replace the siphon break if the reed valve is
cracked or if the reed valve material has hardened
or deteriorated.
2.5
Install the reed valve into the mounting base with
the valve downward. See Figure 5, item 3.
2.6
Install and only finger tighten the retaining cap. Do
not overtighten it.
1. Cap
2. Siphon reed valve
3. Mounting base
Figure 5 Siphon Break
3.
Restore the generator set to service.
3.1
Check that the generator set is OFF.
3.2
Reconnect the generator set engine starting
battery, the negative (--) lead last.
3.3
Reconnect the power to the battery charger, if
equipped.

Parts List

Siphon Break Kit
Kit: GM60007-KP1
Qty. Description
2
Grommet, round
1
Hose, 0.63 in. ID (11.5 in.)
1
Hose, 0.63 in. ID (8.0 in.)
2
Clamp, hose (0.69/1.25 in.)
1
Valve, siphon break
2
Connector, hose
1
Tubing, clear flexible plastic
1
Clamp, hose (0.25/0.70 in.)
1
2
3
Unique Parts
X-284-7
X-312-16
X-312-61
X-426-12
GM32985
344934
GM34883
X-426-9
3