AEG HD 8960 작동 및 설치 지침 - 페이지 4
{카테고리_이름} AEG HD 8960에 대한 작동 및 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. AEG HD 8960 20 페이지. Electrolux group. operating and installation instructions cooker hood hd 8990, hd 8960
AEG HD 8960에 대해서도 마찬가지입니다: 작동 및 설치 지침 (20 페이지), 작동 및 설치 지침 (20 페이지), 작동 및 설치 지침 (20 페이지), 작동 및 설치 지침 (20 페이지)
For more detailed information about treatment, recovery and recycling of this product,
please contact your local city office, your household waste disposal service or the
shop where you purchased the product.
For the installer
When used as an extractor unit, the hood must be fitted with a 120mm diameter
hose.
When installing the hood, make sure you respect the following minimum
distance from the top edge of the cooking hob/ring surfaces:
electric cookers
gas cookers
The hood can be installed above these heights but for optimum performance it
should be installed at the distance quoted for the appropriate heat source.
The national Standard on fuel-burning systems specifies a maximum depression
of 0.04 mbar in such rooms.
The air outlet must not be connected to chimney flues or combustion gas ducts.
The air outlet must under no circumstances be connected to ventilation ducts for
rooms in which fuel-burning appliances are installed.
The air outlet installation must comply with the regulations laid down by the
relevant local authorities.
When the unit is used in its extractor version, a sufficiently large ventilation hole
must be provided, with dimensions that are approximately the same as the outlet
hole.
National and regional building regulations impose a number of restrictions on
using hoods and fuel-burning appliances connected to a chimney, such as coal or
oil room-heaters and gas fires, in the same room.
Hoods can only be used safely with appliances connected to a chimney if the
room and/or flat (air/environment combination) is ventilated from outside using a
suitable ventilation hole approximately 500-600 cm
of a depression being created during operation of the hood.
If you have any doubts, contact the relevant controlling authority or building
inspectors office.
Since the rule for rooms with fuel burning appliances is outlet hole of the same
size as the ventilation hole, a hole of 500-600 cm
could reduce the performance of the extractor hood.
If the hood is used in its recirculation mode, it will operate simply and safely in the
above conditions without the need for any of the aforementioned measures.
When the hood is used in its extractor function, the following rules must be
followed to obtain optimal operation:
The ducting must be fire retardent, 120mm in diameter and the length should be
no more than:
4
All manuals and user guides at all-guides.com
500 mm
650 mm
large to avoid the possibility
2
, which is to say a larger hole,
2