Kohler 1.1785.002 설치 매뉴얼 - 페이지 22

{카테고리_이름} Kohler 1.1785.002에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler 1.1785.002 41 페이지. Thermostatic electric shower

Kohler 1.1785.002 설치 매뉴얼
Hardwired Connection
Mira Advance Flex Extra (J09N) for use with the Instantmatch by
Whale® Digital Pump
Flex Extra J09N
OFF
ON
BEAB CARE MODE
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE
WIRED PUMP MODE set to
ON or OFF depending which wired
transformer used, see transformer
table.
If you are exchanging this Advance for a previous model (J97) that is using a pump
driver board.
1. Remove and discard the driver board and its ribbon cable connections.
2. Cut the connector block off the end of the 2 wires coming into the shower from
the waste pump.
3. Connect the two wires to the small terminal block on the relay PCB (as shown).
For new hard wired installations many waste pump manufacturers supply the cable
to connect from the shower to the waste pump. If the cable is not supplied then Mira
can supply a 4m length cable (part number 1759.125) This should be installed and
connected as detailed.
1306246-W2-D
Do not
remove label
OFF
ON
BEAB CARE MODE
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE
Whale Instant Match Transformer
SDS236T (755.678), SDS233T (755.617)
SDS135T (755.649)
1 2 3 4 5 6 7
Red
Brown
Jumper Settings and Cable Connection
22
1 2 3 4 5 6 7
10 30 60
1 2
10 30 60
1 2
Black