Kohler 1.1785.005 설치 매뉴얼 - 페이지 29

{카테고리_이름} Kohler 1.1785.005에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler 1.1785.005 41 페이지. Thermostatic electric shower

Kohler 1.1785.005 설치 매뉴얼
Important Cleaning Information
Cleaning
Always read the IMPORTANT SAFETY INFORMATION for your shower.
Cleaning the showerhead
Many household and commercial cleaners, including hand and surface cleaning
wipes contain abrasive and chemical substances that can damage plastics, plating
and printing and should not be used. These finishes should be cleaned with a mild
washing up detergent or soap solution, and then wiped dry using a soft cloth.

Fault Diagnosis

1. Installer Troubleshooting Guide
Refer to section: 'Important Safety Information' first and refer also to 'User Trouble
Shooting Guide'.
The following troubleshooting solutions may require the removal of the cover of the
shower. The cover should only be removed by a competent tradesperson and when
doing so they should be aware of the following:
Isolate the electrical and water supplies before initially removing the
cover.
Make sure Ribbon Cable is disconnected when removing the front
cover and reconnect when maintenance is complete.
Mains connections are exposed when the cover is removed.
Refer to wiring diagram before making any electrical connections.
Make sure all electrical connections are tight to prevent arcing/
overheating.
Make sure all plumbing connections are watertight.
When following these instructions, it is sometimes necessary to examine the
appliance with the electrical and water supplies turned on. It is therefore essential
that the appropriate safe working practices are followed in accordance with the
current Health and Safety Legislation.
If conducting a continuity check using a multimeter, make sure the electrical supply
is ISOLATED.
29
1306246-W2-D