Kohler K-1146 주택 소유자 매뉴얼 - 페이지 7

{카테고리_이름} Kohler K-1146에 대한 주택 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler K-1146 32 페이지. Bath whirlpool
Kohler K-1146에 대해서도 마찬가지입니다: 설치 매뉴얼 (48 페이지), 설치 매뉴얼 (44 페이지), 설치 매뉴얼 (48 페이지)

Kohler K-1146 주택 소유자 매뉴얼
Troubleshooting Procedures (cont.)
Symptoms
2. The system will start but
will not stay ON.
3. Whirlpool stops
automatically.
4. The motor starts but not
all jets fuction.
5. Noisy pump operation.
6. Heater does not operate
(units with heaters only).
Kohler Co.
Probable Causes
F.
The receiver in the pump is
defective.
G. System has a timer kit and the
pump is not switched to the ON
position.
A. The receiver in the pump is
defective.
A. System includes an integral timer
and will turn off automatically
after 18 minutes.
B. Pump has overheated and the
protection devices has activated.
C. GFCI/ELCB circuit has tripped.
A. Jets are closed.
B. Jets are blocked or trim ring
rotation is impeded.
C. Jets not installed correctly.
D. Pump is not supported correctly
and is cavitating.
A. The pump banding straps have
not been cut (models with support
blocks only).
A. No power to heater or it is not
connected to a separate outlet
from the pump.
B. The water temperature is above
104°F (40°C).
7
Recommended Action
F.
Replace the receiver or pump.
G. Refer to the timer kit installation
instructions.
A. Replace the receiver or pump.
A. Verify your system has an
integral timer, if yes, no
additional action is needed.
B. Check for blockage at the motor
vents. Check for suction
blockage. Check for jet blockage.
Remove any blockage and allow
the motor to cool.
C. Identify source fault and correct.
Check that the GFCI/ELCB has
not been tripped. If problem
persists, contact an electrician.
A. Rotate the jet trim ring
counterclockwise to
open/increase flow to the jets.
B. Glue may be obstructing the jet
opening or preventing the jet
trim ring from rotating. Remove
the trim ring and remove excess
glue.
C. Reinstall the jet; check for any
O-ring damage.
D. Review the installation
instructions and verify that the
pump is a the appropriate height
and tat the pump banding straps
(when applicable) have been cut.
A. Using tin snips, cut pump
banding straps.
A. Verify that the heater is
connected to a separate outlet
from the pump and that the
connection has power.
B. As a safety precaution, the heater
will not operate when the water
temperature is above 104°F
(40°C).

1010564-5-J