Kohler K-1198 설치 매뉴얼 - 페이지 15

{카테고리_이름} Kohler K-1198에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler K-1198 48 페이지. Bath whirlpool
Kohler K-1198에 대해서도 마찬가지입니다: 주택 소유자 매뉴얼 (32 페이지), 설치 매뉴얼 (48 페이지)

Kohler K-1198 설치 매뉴얼
Troubleshooting Procedure (cont.)
Symptoms
2. Motor starts, not all jets are
functioning.
3. Whirlpool stops automatically
before 18 minutes.
Pump does not prime. (Models
4.
with support blocks only.)
5. Noisy operation.
6.
Heater does not operate. ("H"
models only)
Kohler Co.
Probable Causes
A. Jet is closed.
B. Jet not installed correctly.
C. Jets are blocked.
A. The GFCI or ELCB trips.
B. Suction blocked.
C. Jets are blocked.
D. Motor overheated and
protection device activated.
A. Pump shimmed too high.
A. Pump banding straps have not
been cut. (Models with support
blocks only.)
B. Jet O-ring dislodged.
A. No power to heater.
B. Water temperature exceeds
104° F (40° C).
C. Heater does not work.
15
Recommended Action
A. Rotate jet trim ring
counterclockwise to open.
B. Reinstall jet; check for O-ring
damage.
C. Remove blockage.
A. Identify source of fault, and
correct.
B. Remove obstruction.
C. Remove blockage.
D. Check for blockage at motor
vents. Remove blockage and
allow motor to cool.
Check for suction blockage.
Remove blockage and allow
motor to cool.
Check for jet blockage. Remove
blockage and allow motor to
cool.
A. Lower pump support bracket.
A. Cut pump banding straps with
tin snips.
B. Remove jet, replace and
lubricate O-ring, and reinstall
jet.
A. Reset the GFCI or ELCB.
B. Allow water to cool and heater
will reengage.
C. Replace heater.
1055820-2-A