Kohler K-12009 설치 및 관리 매뉴얼 - 페이지 25

{카테고리_이름} Kohler K-12009에 대한 설치 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler K-12009 50 페이지. Showerheads
Kohler K-12009에 대해서도 마찬가지입니다: 설치 및 관리 매뉴얼 (17 페이지), 설치 및 관리 매뉴얼 (32 페이지)

Kohler K-12009 설치 및 관리 매뉴얼
Spacer
E-Ring
Missing Tooth
Detent
3. Two-Way Installation
IMPORTANT! This valve is not intended to be used as a shut-off
valve. Do not plug any outlets without completing the two-way
conversion.
Two-Way Conversion
Temporarily remove the plaster guard.
Rotate the detent until positioned vertically, as illustrated.
Verify the missing tooth is oriented up.
IMPORTANT! If the internal plug is not removed, the finished wall
will need to be removed to perform this step at a later date.
Using a 1/4" hex wrench, remove and discard the internal plug
from inside the valve body.
Plug the unused port (left or right) with a 1/2" NPT plug (not
included).
Using a pliers, remove the spacer from beneath the detent.
Push the detent in; ensure the points of the detent engage the
notches of the valve cartridge.
Install the spacer above the detent and under the E-ring.
Install the Two-Way Valve
Install 1/2" copper tubing or piping for both accessories. Securely
fasten the piping and outlet ells to the framing.
Kohler Co.
Accessory #2
Accessory #1
Water Line
Water Line
1/2"
Plaster
NPT Plug
Guard
5
Internal
Plug
1205548-2-B