Venting

Venting through a Vent Hose

The vent hose expelling the hot air should be 100 mm diameter and no
longer than 4 meters. Avoid bends in the vent hose as this will reduce
the air flow. The maximum length of the vent hose may be:
4 meters with 0 bends, or
2 meters with 2 bends.
If the vent hose is to be permanently installed to the outside, a wall
vent kit or suitable cover should be used on the outside wall.
Example:
A vent hose (Part number: 647 000 010) and wall vent kit (Part number:
647 000 020) are available from your local AEG Service Force Centre.
Ensure the vent hose is not squashed. The drying efficiency of the
tumble dryer will be affected and may cause the safety cut outs to
operate.
1
Warning! The vent hose must not be connected to a flue pipe or
chimney designed to carry the exhaust from a fuel burning heating
appliance.
13