10. Troubleshooting Procedures
Troubleshooting Table
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale distributor.
Symptoms
1. Whirlpool does not
p
start/stop.
start/stop
2. Motor starts, all jets
j
are not functioning.
are not functioning
3. No air from jets
j
during operation
during operation.
Kohler Co.
Probable Causes
A. No power to motor.
B. Air switch in motor does not work.
C. Air actuator tubing is disconnected,
loose, kinked, plugged, or damaged.
D. Air actuator does not work.
E. Pump/motor does not work.
A. Jet trim is installed incorrectly.
B. Jets are blocked.
C. Suction is blocked.
A. Air line is blocked.
B. Suction line is blocked.
Recommended Action
A. Set/Reset GFCI breaker; check wiring.
B. Replace air switch.
C. Connect, straighten, clean, or replace air
actuator tubing.
D. Replace air actuator.
E. Rebuild or replace pump/motor.
A. Reinstall jet trim.
B. Remove blockage.
C. Remove blockage.
A. Remove blockage, or replace air line.
B. Remove blockage.
9
A
1011585-2-