Turn the jet trim ring
clockwise to
decrease the flow.
Turn the jet trim ring counterclockwise
to increase the flow.
12. Confirm Proper Operation
Fill the Whirlpool
NOTE: Please read these steps carefully before you operate your whirlpool.
Position the jet nozzles so they face down toward the basin. Turn the jet trim rings fully
counterclockwise.
Fill the whirlpool to a water level at least 2" (5.1 cm) above the top of the highest jet.
NOTE: The water temperature in the whirlpool should not exceed 104° F (40° C).
Operating Sequence
Press the air actuator to turn on the whirlpool jets.
Adjust each jet for optimum air/water mixture. Turn the trim ring clockwise to reduce the air flow,
and counterclockwise to increase the air flow.
If equipped with a heater, the heater will engage automatically when the pump is turned on and
will disengage when the pump is turned off. The heater will not turn on if the water temperature
exceeds 104° F (40° C).
Press the air actuator a second time to turn off the whirlpool.
13. Troubleshooting Procedure
Troubleshooting Guide
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct any electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Symptoms
1. Whirlpool does not start or
stop.
Kohler Co.
Fill with water 2" (5.1 cm)
above the highest jet.
Position the jet
nozzles to direct
the water flow as
desired.
Probable Causes
A. No power to motor.
B. Air actuator does not work.
C. Air actuator tubing is
disconnected, loose, kinked,
plugged, or damaged.
Press the air actuator to turn
on and off the whirlpool.
Recommended Action
A. Set/reset the GFCI or ELCB;
B. Replace air actuator.
C. Connect, straighten, clean, or
11
check wiring.
replace air actuator tubing.
1012295-2-D