4. ADJUSTMENTS
TO ADJUST WATER LEVEL
Make sure the refill tube is inserted into the overflow tube. Check
that the water level is at the water line inside the toilet tank. If the
level is off, hold the middle of the float rod, and carefully bend the
rod up or down as needed.
TO ADJUST REFILL TIME
To adjust the refill time, first loosen the locknut. Turn the timing
screw clockwise to increase the refill time; counterclockwise to
decrease the time. After adjustment, tighten the locknut.
Kohler Co., Kohler, WI U.S.A.
Refill Tube
Float Rod
Fig. #11
Refill Tube
Float Rod
Fig. #12
5
Overflow
Tube
Water
Level
Overflow
Tube
Water
Level