Oil Cooler (if equipped)
1. Clean fi ns with a brush or compressed air.
2. Remove two screws securing oil cooler, and
tilt to clean back side.
3. Reinstall oil cooler.
Air Cooling
Hot Parts can cause severe
burns.
Do not touch engine while
operating or just after stopping.
Never operate engine with heat shields or
guards removed.
Proper cooling is essential. To prevent over
heating, clean screens, cooling fi ns, and other
external surfaces of engine. Avoid spraying
water at wiring harness or any electrical
components. See Maintenance Schedule.
Repairs/Service Parts
We recommend that you use a Kohler
authorized dealer for all maintenance,
service, and replacement parts for engine.
To fi nd a Kohler authorized dealer visit
KohlerEngines.com or call 1-800-544-2444
(U.S. and Canada).
24 590 48 Rev. --
WARNING
KohlerEngines.com
Leakage Check/Testing
With fuel valve fully opened, engine not
running, turn key switch ON. Check all fuel
system connections and lines for leaks using
soapy water. Any leakage must be corrected
before restarting engine. Have service
performed by a Kohler authorized dealer or
qualifi ed LPG/NG personnel only.
Storage
If engine will be out of service for 2 months or
more follow procedure below.
1. Change oil while engine is still warm from
operation. Remove spark plug(s) and pour
about 1 oz. of engine oil into cylinder(s).
Replace spark plug(s) and crank engine
slowly to distribute oil.
2. Disconnect negative (-) battery cable.
3. Separate LPG tank from unit and store
separately in an area designated for safe
LPG tank storage.
4. Store engine in a clean, dry place.
9