Kohler 17RESL 운영 - 페이지 13

{카테고리_이름} Kohler 17RESL에 대한 운영을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler 17RESL 48 페이지. Residential/commercial generator sets
Kohler 17RESL에 대해서도 마찬가지입니다: 설치 매뉴얼 (40 페이지)

Kohler 17RESL 운영

1.1 Specifications

The generator set specification sheets provide specific
generator and engine information. Refer to the spec
sheet for data not supplied in this manual. Consult the
generator set service manual, engine operation manual,
and engine service manual for additional specifications.
Obtain copies of the latest spec sheets, manuals,
diagrams, and drawings from your local distributor/
dealer.

1.2 Generator

The generator uses Kohler's unique PowerBoostt
voltage regulation system, which provides instant
response to load changes.
PowerBoostt ensures reliable motor starting and
consistent voltage levels.
voltage excitation system that employs a winding
independent of the main output windings to provide
excitation voltage.

1.3 Engine

The generator set has a four-cycle, twin cylinder, air-
cooled Kohlerr engine. The engine operates on clean-
burning natural gas or propane (LP) vapor. Engine
features include:
D
Efficient overhead valve design and full pressure
lubrication for maximum power, torque, and reliability
under all operating conditions.
D
Dependable, maintenance-free electronic ignition.
D
Precision-formulated cast iron construction of parts
subjected to the most wear and tear.
D
Field-convertible multi-fuel systems that allow fuel
changeover from natural gas to LP vapor (and
vice-versa) while maintaining CARB emission
certification.
D
Digital spark advance optimizes ignition timing for the
selected fuel.
TP-6517 4/09
PowerBoostt utilizes a

Section 1 Features

1.4 Advanced Digital Control

The generator set is equipped with the Kohlerr DC-RET
Digital Control.
Controller features include the
following:
D
Compact controller
D
Integrally mounted to the generator set
D
LED display:
D
Engine runtime, hours
D
Crank cycle status
D
Fault codes
D
Application software version
D
LED display communicates faults:
D
High engine temperature
D
Low battery voltage
D
Low oil pressure
D
Overcrank
D
Overfrequency
D
Overspeed
D
Underfrequency
D
Undervoltage
D
Remote two-wire start/stop capability
Digital voltage regulation: ±1.5% RMS no-load to
D
full-load
D
Automatic start for programmed cranking cycle
D
Master control switch mounted on the junction box:
Run/Off-Reset/Auto
D
Upgradeable application software
Section 1 Features
13