Kohler GEN 5.0 소유자 매뉴얼 - 페이지 10

{카테고리_이름} Kohler GEN 5.0에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler GEN 5.0 44 페이지. Generator
Kohler GEN 5.0에 대해서도 마찬가지입니다: 소유자 매뉴얼 (28 페이지), 서비스 매뉴얼 (20 페이지)

Kohler GEN 5.0 소유자 매뉴얼
Clean Generating Set
1. Remove all dust and debris from around
exhaust.
2. Clean generating set, particularly alternator
and engine air inlets and outlets, using a
cloth and brush.
3. Check general condition of generating set
and replace any faulty parts.
Transporting Generator
Before transporting generator, check that bolts
are correctly tightened, close fuel valve (R)
and disconnect battery. Generator should be
transported in its normal operating position;
never lay it on its side. Ensure where generator
is to be stored or used is carefully prepared
beforehand.
Repairs/Service Parts
We recommend that you use a Kohler portable
dealer for all maintenance, service, and
replacement parts for engine. To find a Kohler
portable dealer visit KohlerPower.com or call
1-800-544-2444 (U.S. and Canada).
10
Storage
Long-term storage of your generator will require
some preventative procedures to guard against
deterioration.
NOTE: Do not connect with any electrical
If engine will be out of service for 2 months or
more follow procedure below.
1. Add Kohler PRO Series fuel treatment or
equivalent to fuel tank. Run engine 2-3
minutes to get stabilized fuel into fuel system
(failures due to untreated fuel are not
warrantable).
2. Change oil while engine is still warm from
operation. Remove spark plug (K) and pour
about 1 oz. of engine oil into cylinder(s).
Replace spark plug (K) and crank engine
slowly to distribute oil.
3. Clean generator.
4. Store generator in a dry, well-ventilated
place, with cover placed over it. When
covering generator, be sure to do so only
after engine and muffler/shield have
completely cooled down. Generator must
remain in same position as normal operation.
5. Store generating set in a clean and dry
place.
KohlerPower.com
devices (unloaded operation).
37 590 02 Rev. F