Kohler GM62346 설치 지침 매뉴얼 - 페이지 7

{카테고리_이름} Kohler GM62346에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Kohler GM62346 8 페이지. 6--60 kw residential and light commercial generator sets

Kohler GM62346 설치 지침 매뉴얼
15RES(A)/R(E)YG and 30RES(A)/R(E)YG
1.
Before working on the generator set or connected
equipment, disable the generator set as follows:
a.
Press the OFF button on the generator set controller.
b.
Disconnect the power to the battery charger.
c.
Remove the battery cables, negative (--) lead first.
2. Release the retaining clips to open the housing and
then remove the air cleaner element.
3. Remove and discard the old air cleaner element.
4. Install the new element.
5. Wipe the cover and housing with a clean rag. Make
sure the sealing surfaces fit correctly and reattach
the retaining clips.
6. Reconnect the battery cable, negative (--) lead last.
2
1
6
1. Cover
2. retaining clip(s)
3. Housing
Figure 9 Air Cleaner; 15RES(A)/R(E)YG, and
30RES(A)/R(E)YG
TT-1445
7/16
4
3
GM21379
5
4. Pressure tap (1/8--27 NPT)
5. Primary element
6. Dust ejector
24RCL, 30RCL, 38RCLB, 48RCLA, and 60RCL
1.
Before working on the generator set or connected
equipment, disable the generator set as follows:
a.
Press the OFF button on the generator set controller.
b.
Disconnect the power to the battery charger.
c.
Remove the battery cables, negative (--) lead first.
2. Release the retaining clips to open the housing and
then remove the air cleaner element.
3. Remove and discard the old air cleaner element.
4. Install the new element.
5. Wipe the cover and housing with a clean rag. Make
sure the sealing surfaces fit correctly and reattach
the retaining clips.
6. Reconnect the negative battery cable and spark
plug lead(s).
2
1
5
1. Cover
2. retaining clip(s)
3. Housing
Figure 10 Air Cleaner; 24/30/60RCL, 48RCLA, and
38RCLB
3
4
GM90280
4. Primary element
5. Dust ejector
7