AQC MAXIHYDRO MS-010 소유자 매뉴얼 - 페이지 12

{카테고리_이름} AQC MAXIHYDRO MS-010에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AQC MAXIHYDRO MS-010 14 페이지.

11 MAINTENANCE AND INSPECTION
The chart indicated below shows different inspections and the frequency at which they should be
performed.
Frequency of
inspections
Daily
Monthly
Yearly

12 TROUBLESHOOTING

Problem
Insufficient suction
of the dust collector
There is dust coming
out at the exit of the
dust collector
There is water esca-
ping from the exit
12
Components
Tank
Tank
Dust collector
Probable cause
Water level too high
There is too much mud. Empty the tank, clean and fill it with new water.
Water level too low.
The supply solenoid
valve does not work.
Elimination panels are
improperly installed.
There are leaks in the
inspection panels.
Procedures
Check that the water level is adequate and that
the fleet is functioning well.
Check for mud build-up, clean if necessary.
Check to see if the water is very black and muddy.
If so, the dust collector should be cleaned.
Inspect, clean and touch up paint if necessary.
Check the valves and the fleet.
Adjust the water level, check the water supply system.
Adjust the water level, check the fleet system.
Check if the solenoid valve is supplying water.
Repair or change it as needed.
Check that the panels are incorrectly installed, check
that everything is properly fixed. Correct as needed.
Check that there are no leaks. Correct as needed.
Wet type dust collector
Solution