4.2. Sensor Output
Path
Main Window → View→ Sensor Output
Level 0
Check the boxes beside any Sensor Outputs you wish to view for monitoring operations.
The table below describes the Sensor Outputs relevant to this module
Item
ComTech Detected Noise
ComTech Min Lock Signal
ComTech Min Valid Signal
ComTechRx Lock
ComTech Rx Signal
ComTech Signal Average
ComTech Signal Gradient
AvL Technologies
Figure 7 - Sensor Output
Noise reading as reported by the AAQ
Signal Level required for the modem to declare lock
Signal Level required from modem for AAQ to be able to peak.
This flag indicating that the modem is locked on carrier.
This is the indicator of signal level in SNR from the modem.
This is the average signal as read from AAQ
Mathematical approximation of signal change over time in coordination
with "Comtech Gradient Sample Time" config. Item as read from AAQ.
ǀ