"LPS" (Compressor Low Pressure)
• Evaporator coil dirty.
• Fan motor not running.
• Low refrigerant pressure.
• Defective low-pressure switch.
• Low ambient air temperature.
"ESO"
• Evaporator temperature sensor connection opened. Check for cut or loose sensor wiring
or defective sensor.
"tSO"
• Water temperature sensor connection opened. Check for cut or loose sensor wiring or
defective sensor.
"ESS"
• Evaporator temperature sensor connection shorted. Check for a short in sensor wiring or
defective sensor.
"tSS"
• Water temperature sensor connection shorted. Check for a short in sensor wiring or
defective sensor.
"DEF"
• Heat pump in defrost cycle.