Aqua Cooler BF200 Series 사용 및 관리 매뉴얼 - 페이지 2

{카테고리_이름} Aqua Cooler BF200 Series에 대한 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Cooler BF200 Series 5 페이지.

INSTALLATION

1.
All UrbanFF Fountains must be installed by a qualified plumber in accordance with National plumbing and
drainage code AS/NZS 3500.1 and AS/NZS 3500.2 and any local authority codes.
2.
Before Installation FLUSH ALL EXTERNAL LINES before connecting to fountain.
3.
Provide adequate level surface for mounting fountain as specified in local area codes (approx. 1400mm
square x 125 mm deep minimum concrete slab) and install an inground fixing cage (preferred method of
installation) or alternatively (remove main acces panel) and mark the anchor points for the fountain to be
dyna-bolted or chemset in place after the concrete slab has been poured.
4.
In BF200C catchment model water inlet through the slab at dimensions shown on Diagram A.
5.
Remove the fountain from the packaging preventing scratching and damage.
6.
All fountains have been checked for leaks as part of our quality assurance program and some droplets of
water may be evident inside the packaging and/or unit. This is perfectly normal.
7.
Remove access panel from fountain using 4mm allen key.
8.
Mount the fountain in place aligning the base holes with the inground fixing cage/anchor markers and
tighten the bolts.
9.
Connect the 40mm waste outlet pipe to the waste water connection (BF200C Catchment model only)
10.
If you have not flushed the external water inlet pipes – do it now! Flushing the water inlet pipes from the
mains supply before connecting to fountain will help prevent blockage by any debris that may be in the
external pipes.
11.
Connect water supply to 1/2" BSP inlet
12.
Test the bubbler by activating the button
13.
Adjust bottle filler flow rate externally as required so mains water pressure (varies from city to city)
isconsistent.
14.
Refer to trouble shooting guide if you experience any problems
15.
Check all connections and waste piping to ensure they are tight and secure
16.
Re-install the access panel once satisfied the fountain is installed correctly
IMPORTANT
THIS UNIT MUST BE INSTALLED BY AN AUTHORISED PLUMBER
THE UNIT TO BE CONNECTED IN ACCORDANCE WITH
AS/NZS 3500.1 or AS/NZS 3500.2
Attention Plumbers:
• This fountain uses "Push In Fittings". Failure to release these fittings correctly will result in leakage.
• These quick release fittings allow instant connection and disconnection without the use of spanners.
Your Partner in Cool.
2

FEATURES AND SPECIFICATIONS

Specifications
3/8" bsb water inlet (15mm)
40mm waste outlet (BF200C Model only)
Maximum Temperature: 40 c
Maximum Water Pressure: 1000 kpa
Complies with WMTS-105 Technical Specification: Appliances - Beverage dispensers and icemakers
Complies with AS/NZS 4020 Testing of products in contact with drinking water
3