dryer ducts. The main duct can be rectangular or round, provided adequate air flow is
maintained. For each individual dryer, the total exhausting (main discharge duct plus
duct outlet from the dryer) should not exceed the equivalent of 20 ft. (6 m) and two
elbows. The diameter of the main discharge duct at the last dryer must be maintained to
exhaust end.
NOTE: A small diameter duct will restrict air flow; a large diameter duct will reduce air velocity
- both contributing to lint build up. An inspection door should be provided for periodic clean-out
of the main duct.

DRYER SHUTDOWN

To render the dryer inoperative, turn off the manual gas shut-off valve and disconnect electrical
supply to the dryer.
Maximum Load Capacity: 25Kg Dry Weight
1. Deposit coins to satisfy vend price display of idle dryer. Each deposit decreases the vend price
until the display changes to show the amount of time purchased. WARM light illuminates.
2. Select drying cycle. Other cycle selections may be made now or later by pressing the
appropriate key (button).
3. Close the loading door. Press "START" and the dryer will start. The time remaining is
displayed in whole minutes (rounded up) and will count down each minute. The colon flashes on
and off indicating the timer is counting down.
4. Clothes should be removed promptly after the cycle is completed to prevent excessive
wrinkling.
Once started, the "timer" cannot be stopped. However, extra coins will be acknowledged by
adding time to the display. The dryer may be stopped by opening the loading door which
interrupts the drive motor and gas burners. Close the loading door and push "START" to restart
the dryer.
Cool-down time (owner programmable) is always part of the cycle time and is purchased by the
customer. For example, if cool-down time is 2 minutes, the last two minutes of the cycle will
have no heat.

OPERATING INSTRUCTIONS

-10-